Fluke ii900 Sonic Industrial Imager |
Definitions |
| Sensors |
| # of microphones |
64 digital MEMS microphones |
Micro-Electro-Mechanical Systems, or MEMS refers
to miniaturized mechanical and electro-mechanical
elements |
| Frequency band |
2 kHz to 52 kHz |
|
| Sound pressure sensitivity |
Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet*
(Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters) |
|
| Operation distance range |
0.5 to > 50 meters (1.6 to > 164 feet) |
|
| Field of view |
63°± 5° |
|
| Minimum frame rate |
12.5 FPS |
The number of Frames Per Second (FPS) indicates
the number of times the images on the screen is
refreshed each second |
| Built-in digital camera (visible light) |
| Field of view (FOV) |
63°± 5° |
|
| Focus |
Fixed lens |
|
| Display 7” |
LCD with backlight, under-sunlight readable |
|
| Resolution |
1280 x 800 (1,024,000 pixels) |
|
| Touchscreen |
Capacitive |
Extremely precise & quick responding |
| Acoustic image |
Yes, SoundMap™ image |
SoundMap™ is a visual map of noise sources using
an acoustical array |
| Image storage |
|
|
| Storage capacity |
Internal memory with the capacity for 999 picture files & 20 video files |
|
| Image format |
Blended visual & SoundMap™.JPG or .PNG |
|
| Video format |
Blended visual & SoundMap™.MP4 |
|
| Video length |
30 seconds |
|
| Digital export |
Yes, SoundMap™ image |
|
| Acoustic measurements |
|
|
| Measurement range |
29.7 dB to 120 dB SPL at 2kHz
16 dB to 106.3 dB SPL (± 1 dB) at 19 kHz
21.4 dB to 117 dB SPL (± 1 dB) at 52 kHz |
Sound pressure level (dB SPL) or acoustic pressure is the local pressure deviation from the ambient– decible & sound pressure level |
| Auto max/min dB gain |
Blended visual & SoundMap™.JPG or .PNG |
|
| Frequency band selection |
User selectable through user-made presets or manual entry |
|
| Software |
|
|
| Ease of use |
Intuitive user interface |
|
| Trend graphs |
Blended visual & SoundMap™.JPG or .PNG |
|
| Spot markers |
dB level reading at center point of the image |
|
| Battery |
|
|
| Batteries (field-replaceable, rechargeable) |
Rechargeable Li-ion, Fluke BP291 |
|
| Battery life |
6 hours (product includes spare battery) |
|
| Battery charging time |
3 hours |
|
| Battery charging system |
External dual-bay charger, EDBC 290 |
|
| General specifications |
|
|
| Standard palettes |
3: Rechargeable Li-ion, Fluke BP291 |
|
| Operating Temperature |
0 °C to 35 °C ( 32 °F to 95 °F) |
|
| Storage Temperature |
-20 °C to 70 °C ( -4 °F to 158 °F) |
|
| Relative humidity |
10 % to 95 % non-condensing |
|
| Size (H x W x L) |
186 mm x 322 mm x 68 mm |
|
| Weight (battery included) |
1.7 kg (3.75 pounds) |
|
| Main unit rating |
IP40 protection against particles 1mm or greater & dripping water |
|
| Sensor head rating |
IP51 |
|
| Warranty |
2 year |
|
| Self-diagnostic notification |
Array-health test to identify when microphone array needs attention |
|
| Supported languages |
Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
|
| RoHS compliant |
Yes |
|
| Safety |
|
|
| General Safety |
IEC 61010-1 |
|
Electromagnetic Compatibility (EMC)
International |
IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A |
|
| Korea (KCC) |
Class A Equipment (Industrial Broadcasting and Communication) |
|
| USA (FCC) |
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 |
|