Laserliner CondenseSpot XP

£219.99 Price incl. VAT: £263.99

Professional non-contact climate/humidity temperature meter for localising thermal bridges and condensation with Bluetooth interface.

  • Surface temperature
  • Dew-point temperature
  • Ambient temperature
  • Wet-bulb temperature
  • Relative humidity

Supplied with:

  • CondenseSpot XP | Hard Case |
  • 2 x 1.5V Alkaline Batteries (type AAA)
  • 4 Year Warranty
Compare
Description

Professional climate/humidity temperature meter for localising thermal bridges and condensation with Bluetooth interface

  • Functions: Surface-, ambient-, dew point-, contact-, wet-bulb temperature, relative humidity
  • Bluetooth interface for measurement data transfer
  • Non-contact temperature measurement in difficult-to-reach places and in hazardous measuring zones
  • Localisation of thermal bridges and condensation water hazards in thermal bridge mode with dew point display
  • Connection for K-type temperature sensor
  • Hygrometer functions: Determine the relative air humidity and ambient temperature and calculate the dew-point temperature
  • Condensation water indicator as bar graph display
  • Colour alarm function: Thermal bridge warning with colour display
  • Min/Max/AVG/Dif function: The smallest, largest, average or difference infrared measured value can be displayed
  • Adjustable emissivity (0.01 – 1.0) with quick selection of 5 memory locations
  • Memory function: 50 storage locations
  • Measurement display in °C or °F, selectable
  • Data-Hold: The most recent measured values are saved temporarily.
  • The multifunction display shows different measured values simultaneously
  • Sturdy, ergonomically designed, rubberised casing

Supplied with:

  • CondenseSpot XP
  • Hard Carry Case
  • 2 x 1.5V Alkaline Batteries (type AAA)
  • 4 Year Warranty
Laserliner ThermoSpot XP - colour alarm function:
Laserliner CondenseSpot XP - Thermal Bridge Mode

Thermal Bridge Mode

Localisation of thermal bridges and condensation water hazards in thermal bridge mode with dew point display.

Laserliner CondenseSpot XP - Functions

Functions

Surface , ambient , dew point , contact , wet-bulb temperature, relative humidity.

Laserliner CondenseSpot XP - Non Contact

Non-contact

Non-contact temperature measurement in difficult-to-reach places and in hazardous measuring zones.

Colour alarm function

Deviations from the desired temperature range are indicated in colour.

Video Tutorial

The CondenseSpot XP allows the precise measurement of surface, ambient, dew point, contact & wet bulb temperatures as well as relative humidity.

Key Features

  • Non-contact temperature measurement for hazardous or difficult-to-reach places
  • Localisation of thermal bridges and condensation water hazards in thermal bridge mode with dew point display
  • Connection for K-type temperature sensor
  • Hygrometer functions: Determine the relative air humidity and ambient temperature and calculate the dew-point temperature
Overview Applications
Measurement Range: -40 °C … 1472 °C Sensitive surfaces
Laser: 8 point laser circle Hazardous areas
OPTIC 30:1 (30 m distance : 1 m measured spot) Live electrical installations

CondenseSpot XP
Documentation

View and download this product’s brochure, datasheet, and manual in a PDF format

Additional information
Brand

Laserliner

Product Specification

Product Specification

CondenseSpot XP
Infrared Temperature: -40°C…800°C / -40°F…1472°F
-40°C…0°C / -40°F…32°F
(± (1°C + 0,1°C / 1°C)) /
(± (1,8°F + 0,18°F / 1°F))
0°C…33°C / 32°F…91,4°F
(± 1°C / ± 1,8°F or ± 1%
depending on the higher value)
>33°C / >91,4°F
(± 2°C / ± 3,6°F or ± 2%
depending on the higher value)
Display Resolution: 0,1°C / 0,1°F / 0,1%rH
Ambient Temperature / Wet-Bulb Temperature: -20°C…65°C / -4°F…149°F
0°C…50°C / 32°F…122°F (± 1°C / ± 1,8°F)
<0°C and >50°C / <32°F and >122°F
(± 2,5°C / ± 4,5°F)
Relative Humidity: 1%…99%, 20%…80% (± 3%)
<20% and >80% (± 5%)
Dew Point Temperature: -50°C…50°C / -58°F…122°F
41%rH…95%rH (± 1,5°C / ± 2,7°F)
31%rH…40%rH (± 2°C / ± 3,6°F)
20%rH…30%rH (±2,5°C / ± 4,5°F)
Contact Temperature K-Type: -30°C…1372°C / -22°F…2501,6°F
(± 1°C / ± 1,8°F or ± 1%
depending on the higher value)
Optics: 30:1
(30 m distance : 1 m measured spot)
Emission Coefficient: 0,01 – 1,0 adjustable
Laser: 8-point laser circle
Laser Class: 2, < 1 mW
Laser Wavelength: 650 nm
Storage Conditions: -10…60°C / 14…140°F, 80%rH,
no condensation
Power Supply: Batteries 2 x 1,5 V type AA
Runtime: 20 hours
Operating Conditions: 0…50°C / 32…122°F, 80%rH,
no condensation, max. altitude 2000 m
Radio Module Operating Data: Bluetooth LE 4.x interface
Dimensions (W x H x D): 150 x 205 x 60 mm
Weight: (incl. batteries) 412 g
Warranty

Warranty

4 Year Manufacturer’s Warranty

Sales & Warranty Centre
Summary of Laserliner Manufacturers Warranty

EXPRESS WARRANTY FOR HARDWARE

Laserliner
All Laserliner products are covered by the manufacturers Warranty as stated with each item. Full details are included with the purchased goods, or available upon request. The purchaser is responsible for all carriage and other additional charges incurred when returning the goods to the company under any warranty arrangement.

Limitation of liability

The company shall not be held liable in respect of any loss or damage whether suffered by the purchaser or any customer of the purchaser and whether direct, indirect, consequential, or however else arising. In addition the company cannot be held liable for any loss or damage from defects arising after the goods have been accepted and checked by the purchaser, nor can the company be held liable for incidences of misuse, incorrect storage or improper handling. Any dates specified for the availability of the goods are approximate only and the company shall not be liable for any losses, costs, damages, charges or expenses caused by any delay in delivery of the goods.