Fluke 113 Digital Multimeter

£125.00 Price incl. VAT: £150.00

Uniquely designed for basic electrical measurements. Provides easy and safe access to all common types of electrical measurement.

Supplied with:
  • Fluke 113 Multimeter
  • Test Leads
  • Rubber Boot
  • 9V battery
  • User manual
  • 2 Year Warranty
Compare
Description

Fluke 113 Digital Multimeter

The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic testing. It is easy to-use and has the features needed to repair most electrical problems. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min/Max function lets you record signal fluctuations. The Fluke 113 digital multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.

The Fluke 110 Series has five true-RMS digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.

Supplied with:

  • Fluke 113 Multimeter
  • Test Leads
  • Rubber Boot
  • 9V battery
  • User manual
  • 2 Year Warranty
Fluke 113 Digital Multimeter - Application

Key Features

  • VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity
  • True RMS for accurate AC measurements on non-linear loads
  • A large backlit display allows for easy visibility in low-lit areas
  • Record signal fluctuations using the Min/Max function
  • Diode test for testing general-purpose germanium, silicon, and power diodes
  • Integral holster with probe holders for easy storage
  • Auto and Manual ranging for added user functionality
  • Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety
  • The optional TPAK magnetic hanger allows the user hands-free flexibility
Benefits Applications
Maximum voltage between any terminal and earth ground: 600V Utility Worker
Display: 3 3/4-digits, 6000 counts, updates 4/sec Linesman
Operating temperature: -10°C to 50°C (14°F to 122°F) Electricians
Storage temperature: -40°C to 60°C (-22°F to 140°F) Technicians
Temperature coefficient: 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) Basic electrical testing
Altitude: 2,000 m (operating), 10,000 m (storage)
Relative humidity: 95% to 30°C | 75% to 40°C | 45% to 50°C
Battery type: 9V alkaline
Battery life: 300 hours typical, without backlight
Shock: 1 Meter drop tested (IEC 61010–1–2001)
Vibration: Per MIL-PRF-28800 for Class 2 instrument
Size (H x W x L): 167.1 x 85.1 x 46.0 mm
Weight: 404 g
Safety: Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1
EMI regulations: Complies with FCC Part 15, Class B

113 Digital Multimeter
Documentation

View and download this product’s brochure, datasheet, and manual in a PDF format

Additional information
Brand

Fluke

1AC II VoltAlert

1pk

,

5pk

,

6pk

,

12pk

Product Specification

Product Specification

Product specifications

Function Range Resolution Accuracy
DC, 45 to 500 Hz 500 Hz to 1 kHz
Chek1,2 6.000 V

60.00 V

600.0 V

0.001 V

0.01 V

0.1 V

2.0 % + 3 4.0 % + 3
Function Range Resolution Accuracy
3 2.000 V 0.001 V 2.0 % + 3
3

Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 µs or longer

3 600.0 Ω

6.000 kΩ

60.00 kΩ

0.1 Ω

0.001 kΩ

0.01 kΩ

0.9 % + 2

0.9 % + 1

0.9 % + 1

3 1000 nF

10.00 µF

100.0 µF

9999 µF

1 nF

0.01 µF

0.1 µF

1 µF

1.9 % + 2

1.9 % + 2

1.9 % + 2

100 µF – 1000 µF: 1.9 % + 2
> 1000 µF: 5 % + 20

Notes:

  1. All Chek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
  2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
  3. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
Warranty

Warranty

2 Year Manufacturer’s Warranty

Summary of Fluke Manufacturers Warranty


All Fluke products are covered by the manufacturers Warranty as stated with each item. Full details are included with the purchased goods, or available upon request. The purchaser is responsible for all carriage and other additional charges incurred when returning the goods to the company under any warranty arrangement.

Fluke Product Registration

Fluke Product Registration